Abstract
The ternary equilibrium data for the system acetic acid-mesityl oxide-water were determined at different temperatures. The results showed no significant effect of temperature on the solubility area. However, addition of about 10% sodium chloride increased the area under the binodal curve by more than 40%. The tie line data were also determined. These data proved that mesityl oxide particularly in presence of salt is a promising solvent for acetic acid extraction from aqueous solutions.
| Original language | English |
|---|---|
| Pages (from-to) | 145-150 |
| Number of pages | 6 |
| Journal | Journal of Chemical Technology and Biotechnology, Chemical Technology |
| Volume | 33 A |
| Issue number | 3 |
| DOIs | |
| State | Published - 1983 |
| Externally published | Yes |