Abstract
The study analyses wind-speed data of Yanbu (West-Coast, Kingdom of Saudia, KSA) to assess the feasibility of hybrid wind-diesel power systems to meet the electrical load of hundred typical residential buildings (with annual demand of 3512 MWh). The wind speeds range from 3.9-4.8 m/s. The systems simulated consist of 600 kW wind machines supplemented with diesel generators. NREL's HOMER software is employed for techno-economic analysis. The results indicate that for a hybrid system comprising of 600 kW wind capacity with 1.0 MW diesel system (two 500 kW units), the wind penetration (at 50 m hub-height, with 0% annual capacity shortage) is 27%. The cost of generating energy (COE, $/kWh) from this system is 0.070 $/kWh (assuming diesel fuel price of 0.1$/liter) and the reduction in carbon emissions is 147 tons/year. The study exhibits that the operational hours of diesel gensets decrease with increase in wind farm capacity.
| Original language | English |
|---|---|
| Pages (from-to) | 86-101 |
| Number of pages | 16 |
| Journal | International Journal of Global Warming |
| Volume | 16 |
| Issue number | 1 |
| DOIs | |
| State | Published - 2018 |
Bibliographical note
Publisher Copyright:Copyright © 2018 Inderscience Enterprises Ltd.
Keywords
- Carbon emissions
- Diesel generators
- Hybrid wind-diesel systems
- Residential loads
- Saudi Arabia
ASJC Scopus subject areas
- Global and Planetary Change
- Atmospheric Science
- Management, Monitoring, Policy and Law