Saudi Aramco, like other operators with lean feed acid gas containing benzene, toluene and xylene (BTX) has dealt for years with chronic Claus catalyst deactivation, low sulphur recovery and frequent shutdowns to replace catalyst. After completing an exhaustive process selection study to identify the most cost effective solution to the problem, the company proceeded with installation of regenerable activated carbon beds upstream of the sulphur recovery units (SRUs) to remove aromatics contaminants before they reach the converter beds. Saudi Aramco completed construction of seven BTX removal units to treat acid feeding downstream sulphur plants in December 2005. Commissioning took place in the spring of 2006. This paper discusses design issues, start-up and commissioning experience for the units, their performance and impact on the downstream Claus catalyst. In brief, catalyst deactivation has been virtually eliminated. This has set the foundation to allow us to revamp the units to achieve higher recovery, which would not have been possible until catalyst deactivation had been resolved.

Original languageEnglish
Title of host publicationInternational Petroleum Technology Conference 2007, IPTC 2007
Pages944-957
Number of pages14
StatePublished - 2007
Externally publishedYes

Publication series

NameInternational Petroleum Technology Conference 2007, IPTC 2007
Volume2

Keywords

  • Acid gas
  • Associated gas
  • Sour gas

ASJC Scopus subject areas

  • Geochemistry and Petrology
  • Geophysics
  • Geotechnical Engineering and Engineering Geology
  • Fuel Technology

Fingerprint

Dive into the research topics of 'Saudi Aramco eliminates claus catalyst deactivation caused by aromatics using activated carbon'. Together they form a unique fingerprint.

Cite this