T1 - Retentiveness of metal coping luted to teeth of uremic patients undergoing hemodialysis using five different luting cements
AU - Ghazy, Mohamed H.
AU - Aboumadina, Manal M.
AU - Mahmoud, Salah Hasab
PY - 2014
Y1 - 2014
N2 - Objectives: This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. Methods: A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and water coolant. Metal copings with a loop on the occlusal surface were fabricated using base metal alloy (Rexillium III). The copings were luted using Fuji I, glass ionomer (GI); Fuji Plus, resin-modified glass ionomer (RMGI); Panavia F 2.0, resin cement; Rely X Unicem, self-adhesive cement (SA); and Adhesor, zinc phosphate cement (ZPh). All specimens were incubated at 37°C for 24 hours, conditioned in artificial saliva for 7 days, and then thermocycled for 5000 cycles (5°C-55°C). The dislodging force was measured using a universal testing machine at a crosshead speed of 2 mm/min. The mode of failure of the loaded adhesive copings was evaluated. Statistical analyses were performed using one-way analysis of variance and Tukey post hoc test. Results: GI and SA cements had the highest and the lowest mean retentive strength, respectively (580.90±17.3, 406.6±12.7). There was no significant difference between ZPh, SA, and resin cements. These cements were inferior to GI and RMGI cements (p<0.05), which showed statistically similar retentive strengths. Conclusions: The results of this study support the use of glass ionomer and resin-modified glass ionomer cements for luting of metal copings to uremic teeth with retentive preparations.
AB - Objectives: This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. Methods: A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and water coolant. Metal copings with a loop on the occlusal surface were fabricated using base metal alloy (Rexillium III). The copings were luted using Fuji I, glass ionomer (GI); Fuji Plus, resin-modified glass ionomer (RMGI); Panavia F 2.0, resin cement; Rely X Unicem, self-adhesive cement (SA); and Adhesor, zinc phosphate cement (ZPh). All specimens were incubated at 37°C for 24 hours, conditioned in artificial saliva for 7 days, and then thermocycled for 5000 cycles (5°C-55°C). The dislodging force was measured using a universal testing machine at a crosshead speed of 2 mm/min. The mode of failure of the loaded adhesive copings was evaluated. Statistical analyses were performed using one-way analysis of variance and Tukey post hoc test. Results: GI and SA cements had the highest and the lowest mean retentive strength, respectively (580.90±17.3, 406.6±12.7). There was no significant difference between ZPh, SA, and resin cements. These cements were inferior to GI and RMGI cements (p<0.05), which showed statistically similar retentive strengths. Conclusions: The results of this study support the use of glass ionomer and resin-modified glass ionomer cements for luting of metal copings to uremic teeth with retentive preparations.
UR - https://www.scopus.com/pages/publications/84902506186
U2 - 10.2341/12-523-LR2
DO - 10.2341/12-523-LR2
M3 - Article
C2 - 24191870
AN - SCOPUS:84902506186
SN - 0361-7734
VL - 39
SP - E101-E108
JO - Operative Dentistry
JF - Operative Dentistry
IS - 3
ER -