TY - GEN
T1 - Real-time three-dimensional flexible needle tracking using two-dimensional ultrasound
AU - Vrooijink, Gustaaf J.
AU - Abayazid, Momen
AU - Misra, Sarthak
PY - 2013
Y1 - 2013
N2 - Needle insertion is one of the most commonly performed minimally invasive procedures. Visualization of the needle during insertion is key for either successful diagnosis or therapy. This work presents the real-time three-dimensional tracking of flexible needles during insertion into a soft-tissue simulant using a two-dimensional (2D) ultrasound transducer. The transducer is placed perpendicular to the needle tip to measure its position. During insertion the transducer is robotically repositioned to track the needle tip. Positioning of the transducer is accomplished by a compensator, that uses the needle insertion velocity corrected by needle tip velocities to determine out-of-plane motion. Experiments are performed to validate the needle tip pose during tracking. The maximum mean errors in needle tip position along the x-, y- and z-axes are 0.64 mm, 0.25 mm and 0.27 mm, respectively. The error in tip orientations (θ-about the y-axis and φ-about the z-axis) are 2.68° and 2.83°, respectively. This study demonstrates the ability to compute the needle tip pose using a 2D ultrasound transducer. The tip pose can be used to robotically steer needles, and thereby improve accuracy of medical procedures.
AB - Needle insertion is one of the most commonly performed minimally invasive procedures. Visualization of the needle during insertion is key for either successful diagnosis or therapy. This work presents the real-time three-dimensional tracking of flexible needles during insertion into a soft-tissue simulant using a two-dimensional (2D) ultrasound transducer. The transducer is placed perpendicular to the needle tip to measure its position. During insertion the transducer is robotically repositioned to track the needle tip. Positioning of the transducer is accomplished by a compensator, that uses the needle insertion velocity corrected by needle tip velocities to determine out-of-plane motion. Experiments are performed to validate the needle tip pose during tracking. The maximum mean errors in needle tip position along the x-, y- and z-axes are 0.64 mm, 0.25 mm and 0.27 mm, respectively. The error in tip orientations (θ-about the y-axis and φ-about the z-axis) are 2.68° and 2.83°, respectively. This study demonstrates the ability to compute the needle tip pose using a 2D ultrasound transducer. The tip pose can be used to robotically steer needles, and thereby improve accuracy of medical procedures.
UR - https://www.scopus.com/pages/publications/84887298110
U2 - 10.1109/ICRA.2013.6630797
DO - 10.1109/ICRA.2013.6630797
M3 - Conference contribution
AN - SCOPUS:84887298110
SN - 9781467356411
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 1688
EP - 1693
BT - 2013 IEEE International Conference on Robotics and Automation, ICRA 2013
T2 - 2013 IEEE International Conference on Robotics and Automation, ICRA 2013
Y2 - 6 May 2013 through 10 May 2013
ER -