Performance of an RTL contactor for gas‐liquid systems: Effective interfacial area and volumetric mass transfer coefficient by oxidation of sodium sulphite solution

Erdogan Alper*, Basel Abu‐Sharkh

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Effective interfacial area a and volumetric liquid‐side mass transfer coefficient kLa of an RTL contactor were obtained at different stirring speeds by absorption of oxygen from air into 0.8 kmol/m3 sodium sulphite solution, in the presence of Co++ ions. The values of a and kLa ranged from 80 to 150 m2/m3 and 0.0003 to 0.00053 s−1, respectively, when stirrer speed was increased from 8 to 40 rpm. When kL alone was evaluated, it was found to be practically constant, irrespective of stirring speed.

Original languageEnglish
Pages (from-to)15-19
Number of pages5
JournalChemical Engineering and Technology
Volume12
Issue number1
DOIs
StatePublished - 1989

ASJC Scopus subject areas

  • General Chemistry
  • General Chemical Engineering
  • Industrial and Manufacturing Engineering

Fingerprint

Dive into the research topics of 'Performance of an RTL contactor for gas‐liquid systems: Effective interfacial area and volumetric mass transfer coefficient by oxidation of sodium sulphite solution'. Together they form a unique fingerprint.