Performance comparison of 2.8 MeV and 241Am-Be neutrons based moisture measurement setups

  • M. S. Abdelmonem*
  • , A. A. Naqvi
  • , Hanan Al-Ghamdi
  • , Ghada Al-Misned
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Performance of a 241Am-Be neutron source-based and 2.8 MeV neutrons-based moisture measurement setups have been compared using Monte Carlo simulation. In the setup fast neutrons transmitted through the sample were detected by a fast neutron detector, which was placed behind a massive long double truncated collimator. The setup geometry was optimized to detect maximum effect of 1-7 wt.% moisture on the neutron intensity transmitted through the sample. The yield of neutrons transmitted through concrete, coal, wood and soil samples containing 1-7 wt.% moisture was calculated for 2.8 MeV neutrons and neutrons from an 241Am-Be source. The slopes of the fast neutron intensities transmitted through the samples vs. their moisture contents are very sensitive to the neutron energy and the sample composition. Higher slopes have been observed for the samples with larger bulk density. The slopes of fast neutron yield show dependence on the incident neutron energy. Larger slopes have been observed for neutrons with samller energy. Due to the overall large slopes of the transmitted intensity data of the samples for 2.8 MeV neutrons, it is expected to achieve better sensitivity in moisture measurements for a 2.8 MeV neutrons based moisture setup.

Original languageEnglish
Pages (from-to)131-137
Number of pages7
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume274
Issue number1
DOIs
StatePublished - Oct 2007

Bibliographical note

Funding Information:
The authors acknowledge the support of King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia and Girls Education College, Riyadh Girls Colleges, Riyadh, Saudi Arabia.

ASJC Scopus subject areas

  • Analytical Chemistry
  • Nuclear Energy and Engineering
  • Radiology Nuclear Medicine and imaging
  • Pollution
  • Spectroscopy
  • Public Health, Environmental and Occupational Health
  • Health, Toxicology and Mutagenesis

Fingerprint

Dive into the research topics of 'Performance comparison of 2.8 MeV and 241Am-Be neutrons based moisture measurement setups'. Together they form a unique fingerprint.

Cite this