Performance analysis of a stand-alone pv/wt/biomass/bat system in alrashda village in egypt

  • Hoda Abd El-Sattar
  • , Salah Kamel
  • , Hamdy Sultan
  • , Marcos Tostado-Véliz*
  • , Ali M. Eltamaly
  • , Francisco Jurado
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

17 Scopus citations

Abstract

This paper presents an analysis and optimization of an isolated hybrid renewable power system to operate in the Alrashda village in the Dakhla Oasis, which is situated in the New Valley Governorate in Egypt. The proposed hybrid system is designed to integrate a biomass system with a photovoltaic (PV), wind turbine (WT) and battery storage system (Bat). Four different cases are proposed and compared for analyzing and optimizing. The first case is a configuration of PV and WT with a biomass system and battery bank. The second case is the integration of PV with a biomass system and battery bank. The third case is WT integrated with biomass and a battery bank, and the fourth case is a conventional PV, WT, and battery bank as the main storage unit. The optimization is designed to reduce component oversizing and ensure the dependable control of power supplies with the objective function of reducing the levelized cost of energy and loss of power supply prob-ability. Four optimization algorithms, namely Heap-based optimizer (HBO), Franklin’s and Cou-lomb’s algorithm (CFA), the Sooty Tern Optimization Algorithm (STOA), and Grey Wolf Optimizer (GWO) are utilized and compared with each other to ensure that all load demand is met at the lowest energy cost (COE) for the proposed hybrid system. The obtained results revealed that the HBO has achieved the best optimal solution for the suggested hybrid system for case one and two, with the minimum COE 0.121171 and 0.1311804 $/kWh, respectively, and with net present cost (NPC) of $3,559,143 and $3,853,160, respectively. Conversely, STOA has achieved the best optimal solution for case three and four, with a COE of 0.105673 and 0.332497 $/kWh, and an NPC of $3,103,938 and $9,766,441, respectively.

Original languageEnglish
Article number10191
JournalApplied Sciences (Switzerland)
Volume11
Issue number21
DOIs
StatePublished - 1 Nov 2021
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Li-censee MDPI, Basel, Switzerland.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Biomass system
  • Energy cost
  • Franklin’s and Coulomb’s al-gorithm
  • Heap-based optimizer
  • PV
  • Sooty tern optimization
  • Wind turbine

ASJC Scopus subject areas

  • General Materials Science
  • Instrumentation
  • General Engineering
  • Process Chemistry and Technology
  • Computer Science Applications
  • Fluid Flow and Transfer Processes

Fingerprint

Dive into the research topics of 'Performance analysis of a stand-alone pv/wt/biomass/bat system in alrashda village in egypt'. Together they form a unique fingerprint.

Cite this