T1 - Optimized Energy Control Strategy About Daily Operation of Islanded Microgrid With Wind/Photovoltaic/Diesel/Battery Under Consideration of Transferable Load Efficiency
AU - Wei, Fanrong
AU - Sui, Quan
AU - Lin, Xiangning
AU - Li, Zhengtian
AU - Chen, Le
AU - Deng, Ke
AU - Bo, Zhiqian
AU - Huang, Jingguang
AU - Khalid, Muhammad Shoaib
AU - Adio, Owolabi Sunday
N1 - Publisher Copyright:
© 2018 Chin. Soc. for Elec. Eng.
PY - 2018/2/20
Y1 - 2018/2/20
N2 - Considering the problem that operating schedule of microgrid system with wind/photovoltaic/diesel/storage is not economic enough because of ignoring the efficiency-power characteristics of the large load especially the transferable load in the present stage, a wind/photovoltaic/ diesel/ thermal energy storage optimization strategy with considering transferable load efficiency was put forward in this paper. Firstly, taking the typical transferable load-the reverse osmosis desalination device as an example, a fresh water input-output model during the whole process was established, and the real time power efficiency characteristic curve was calculated. Accounting for the power characteristics of the reverse osmosis system, the battery life (using cost) and the working efficiency of the diesel engine, the energy control strategy of wind/photovoltaic/diesel/thermal storage system was optimized with the minimum operating cost as the objective. By comparing with two typical micro grid energy control schedules, simulation results show that the proposed strategy has a good economic advantage for various potential mixture of battery life and fuel cost with a constant supply demand of fresh water in a micro grid containing a transferable load. The paper provides a new perspective of optimizing the economic operation strategy of microgrid with transferable loads.
AB - Considering the problem that operating schedule of microgrid system with wind/photovoltaic/diesel/storage is not economic enough because of ignoring the efficiency-power characteristics of the large load especially the transferable load in the present stage, a wind/photovoltaic/ diesel/ thermal energy storage optimization strategy with considering transferable load efficiency was put forward in this paper. Firstly, taking the typical transferable load-the reverse osmosis desalination device as an example, a fresh water input-output model during the whole process was established, and the real time power efficiency characteristic curve was calculated. Accounting for the power characteristics of the reverse osmosis system, the battery life (using cost) and the working efficiency of the diesel engine, the energy control strategy of wind/photovoltaic/diesel/thermal storage system was optimized with the minimum operating cost as the objective. By comparing with two typical micro grid energy control schedules, simulation results show that the proposed strategy has a good economic advantage for various potential mixture of battery life and fuel cost with a constant supply demand of fresh water in a micro grid containing a transferable load. The paper provides a new perspective of optimizing the economic operation strategy of microgrid with transferable loads.
KW - Desalination device
KW - Energy control optimization
KW - The power efficiency characteristic
KW - Transferable load
KW - Using cost
UR - https://www.scopus.com/pages/publications/85040454998
U2 - 10.13334/j.0258-8013.pcsee.162499
DO - 10.13334/j.0258-8013.pcsee.162499
M3 - Article
AN - SCOPUS:85040454998
SN - 0258-8013
VL - 38
SP - 1045
EP - 1053
JO - Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering
JF - Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering
IS - 4
ER -