Skip to main navigation Skip to search Skip to main content

Optimization of chromium (VI) reduction in aqueous solution using magnetic Fe3O4 sludge resulting from electrocoagulation process

  • Pınar Belibagli
  • , Zelal Isik
  • , Nadir Dizge*
  • , Deepanraj Balakrishnan
  • , Abdul Rahman Afzal
  • , Muhammad Akram*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

The reuse of electro-coagulated sludge as an adsorbent for Cr(VI) ion reduction was investigated in this study. Electro-coagulated sludge was obtained during the removal of citric acid wastewater by the electrocoagulation process. The following parameters were optimized for Cr(VI) reduction: pH (5–7), initial Cr(VI) concentration (10–50 mg/L), contact time (10–45 min), and adsorbent dosage (0.5–1.5 g/L). Cr(VI) reduction optimization reduction experimental sets were designed using response surface design. Cr(VI) reduction optimization results 97.0% removal efficiency and 15.1 mg/g adsorption capacity were obtained at pH 5.0, 1.5 g/L electro-coagulated Fe3O4 sludge, 10 mg/L initial Cr(VI) concentration and 45 min reaction time. According to the isotherm results, the experimental data are compatible with the Freundlich isotherm model, and since it is defined by the pseudo-second order model emphasizes that the driving forces of the Cr(VI) reduction process are rapid transfer of Cr(VI) to the adsorbent surface. The reusability of the adsorbent was investigated and Cr (VI) reduction was achieved at a high rate even in the 5th cycle. All these results clearly show that electro-coagulated Fe3O4 sludge is an effective, inexpensive adsorbent for Cr(VI) removal from wastewater.

Original languageEnglish
Article numbere0309607
JournalPLoS ONE
Volume19
Issue number12
DOIs
StatePublished - Dec 2024
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2024 Belibagli et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation

ASJC Scopus subject areas

  • General

Fingerprint

Dive into the research topics of 'Optimization of chromium (VI) reduction in aqueous solution using magnetic Fe3O4 sludge resulting from electrocoagulation process'. Together they form a unique fingerprint.

Cite this