Abstract
Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta-analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision-making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high-performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ-based performance gains that can directly inform cost-benefit analyses of building design and renovation.
| Original language | English |
|---|---|
| Article number | 6840369 |
| Journal | Indoor Air |
| Volume | 2025 |
| Issue number | 1 |
| DOIs | |
| State | Published - 2025 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:Copyright © 2025 Kevin Keene et al. Indoor Air published by John Wiley & Sons Ltd.
Keywords
- indoor environmental quality
- office buildings
- productivity
- task performance
ASJC Scopus subject areas
- Environmental Engineering
- Building and Construction
- Public Health, Environmental and Occupational Health
Fingerprint
Dive into the research topics of 'Meta-Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver