Improved analysis of the electrically manifested distortions of condenser microphones

Muhammad Taher Abuelma'atti*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

An improved analysis for the electrically manifested nonlinear distortions in condenser microphones is presented. The analysis shows that in typical condenser microphones excited by multisinusoidal sound signals, the second-order intermodulation components of frequencies ωr±ωs will be dominant. This result suggests that, rather than using the total harmonic distortion (THD), the use of the standard two- or three-tone tests for measurement of the nonlinear performance of condenser microphones would be more reliable and sensible.

Original languageEnglish
Pages (from-to)471-480
Number of pages10
JournalApplied Acoustics
Volume64
Issue number5
DOIs
StatePublished - May 2003

Keywords

  • Condenser microphones
  • Harmonic and intermodulation distortion

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Fingerprint

Dive into the research topics of 'Improved analysis of the electrically manifested distortions of condenser microphones'. Together they form a unique fingerprint.