Skip to main navigation Skip to search Skip to main content

Hyperemia-free delineation of epicardial and microvascular impairments using a basal index

  • Kranthi K. Kolli
  • , M. A. Effat
  • , Srikara V. Peelukhana
  • , Paul Succop
  • , Lloyd H. Back
  • , M. A. Leesar
  • , T. A. Helmy
  • , Arif Imran
  • , R. K. Banerjee*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

3 Scopus citations

Abstract

The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%. The bCDP, a parameter based on fundamental fluid dynamics principles, was calculated as the transtenotic pressure-drop divided by the dynamic pressure in the distal vessel, measured under baseline (without hyperemia) conditions. The group mean values of bCDP for normal (84 ± 18) and abnormal (124.5 ± 15.6) microcirculation were significantly different. Similarly, the mean values of bCDP from AS < 50% (72.5 ± 16.1) and AS > 50% (136 ± 17.2) were also significantly different (p < 0.05). The bCDP could significantly distinguish between lesions of AS < 50% to AS > 50% under normal microcirculation (52.1 vs. 85.8; p < 0.05) and abnormal microcirculation (84.9 vs. 172; p < 0.05). Further, the bCDP correlated linearly and significantly with the hyperemic parameters FFR (r = 0.42, p < 0.05) and CDP (r = 0.50, p < 0.05). The bCDP is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment. We believe that it has an immediate appeal for detection of coronary artery disease if validated clinically.

Original languageEnglish
Pages (from-to)1681-1690
Number of pages10
JournalAnnals of Biomedical Engineering
Volume42
Issue number8
DOIs
StatePublished - Aug 2014
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • CDP
  • CFR
  • Catheterization
  • Coronary disease
  • FFR
  • Hyperemia-free index

ASJC Scopus subject areas

  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Hyperemia-free delineation of epicardial and microvascular impairments using a basal index'. Together they form a unique fingerprint.

Cite this