Skip to main navigation Skip to search Skip to main content

Functional diagnosis of coronary stenoses using pressure drop coefficient: A pilot study in humans

  • Kranthi K. Kolli
  • , Tarek A. Helmy
  • , Srikara V. Peelukhana
  • , Imran Arif
  • , Massoud A. Leesar
  • , Lloyd H. Back
  • , Rupak K. Banerjee
  • , Mohamed A. Effat*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

14 Scopus citations

Abstract

Objectives and Background Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV). The CDP is a nondimensional ratio, derived from fundamental fluid dynamic principles. We sought to evaluate the correlation of CDP with FFR, CFR, and hyperemic stenosis resistance (HSR: ratio of pressure drop to APV) in human subjects. Methods Twenty-seven patients with reversible perfusion defects based on SPECT were consented for the study before cardiac catheterization. Distal coronary pressure and APV were measured simultaneously for each coronary lesion using a Combowire© during cardiac catheterization. Reference diameter, minimal lumen diameter, and %AS were obtained by quantitative coronary angiography. Maximum hyperemia was induced by IV adenosine (140 μg/kg/min). CDP was calculated as, (Δp)/(0.5 × ρ × APV2). The density of blood (ρ) was assumed to be 1.05 gm/cm3. Results The functional index, CDP, when correlated simultaneously with FFR and CFR, was found to have a significant correlation (r = 0.61; P < 0.05). Similarly a significant correlation was achieved when CDP was correlated with HSR (r = 0.91; P < 0.001). This is consistent with the definition of CDP, which is a functional parameter that includes both pressure and flow information. Conclusions CDP, a nondimensional parameter combining simultaneous measurements of pressure drop and velocity data, can accurately define the severity of coronary stenoses and could prove advantageous clinically. © 2013 Wiley Periodicals, Inc.

Original languageEnglish
Pages (from-to)377-385
Number of pages9
JournalCatheterization and Cardiovascular Interventions
Volume83
Issue number3
DOIs
StatePublished - 15 Feb 2014
Externally publishedYes

Keywords

  • cardiac hemodynamics
  • catheterization
  • coronary disease
  • stenosis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Functional diagnosis of coronary stenoses using pressure drop coefficient: A pilot study in humans'. Together they form a unique fingerprint.

Cite this