Fetal biometry: Size and configuration of the third ventricle

  • A. Sari*
  • , A. Ahmetoglu
  • , H. Dinc
  • , A. Saglam
  • , U. Kurtoglu
  • , S. Kandemir
  • , H. Reşit Gümele
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Purpose: To evaluate the normal configuration and size of the third ventricle in second and third trimester fetuses in a normal population, and to compare our values with those of previously published studies. Material and Methods: Evaluation of fetal third ventricular width and configuration was obtained by antenatal ultrasonography in 474 fetuses with gestational age between 12 weeks and term (mean 28 weeks). Percentiles for third ventricle width were estimated by combining separate fractional polynominal regression models fitted to the mean and standard deviation, assuming that the measurements had a normal distribution at each gestational age. Appearance of the third ventricle was correlated with each gestational age. Results: The third ventricle could be visualized in 471 (99%) of 474 fetuses. The 97th percentile of the third ventricle in preterm fetuses was measured as 3.6mm in size. The third ventricle was seen as a single echogenic line in 153 (32.4%) of 474 fetuses. Twohundredandninetynine (61.5%) of all fetuses had parallel echogenic lines outlining a fluidfilled lumen. Vshaped third ventricular configuration was seen in only 28 (5.9%) of the fetuses. From 24 weeks to term, parallel echogenic lines were the most commonly (83.7% to 79.6%) encountered configuration for the third ventricle. Conclusion: The 97th percentile of the third ventricle in preterm fetuses was measured as 3.6mm in size. In the early second trimester, 77% of the fetuses had a single echogenic line appearance on ultrasonography. As the brain and ventricular structures mature, a parallel echogenic line becomes the prominent ultrasonography appearance (>80% of fetuses) in third trimester healthy fetuses.

Original languageEnglish
Pages (from-to)631-635
Number of pages5
JournalActa Radiologica
Volume46
Issue number6
DOIs
StatePublished - Oct 2005
Externally publishedYes

Keywords

  • Configuration
  • Normal fetus
  • Size
  • Third ventricle
  • Ultrasonography

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Fetal biometry: Size and configuration of the third ventricle'. Together they form a unique fingerprint.

Cite this