Abstract
The fabrication of miniaturized electrical biosensing devices can enable the rapid on-chip detection of biomarkers such as miRNA molecules, which is highly important in early-stage cancer detection. The challenge in realizing such devices remains in the miniaturization of the reference electrodes, which is an integral part of electrical detection. Here, we report on a novel thin film Ag/AgCl reference electrode (RE) that has been fabricated on top of a Au-sputtered glass surface, which was coated with a self-assembled monolayer (SAM) of 6-mercepto-1-hexanol (MCH). The electrode showed very little measurement deviation (-1.5 mv) from a commercial Ag/AgCl reference electrode and exhibited a potential drift of only ± 0.2 mV/h. In addition, the integration of this SAM-modified microfabricated thin film RE enabled the rapid detection (<30 min) of miRNA (let-7a). The electrode can be integrated seamlessly into a microfluidic device, allowing the highly stable and fast measurement of surface potential and is expected to be very useful for the development of miniature electrical biosensors.
| Original language | English |
|---|---|
| Article number | 2326 |
| Journal | Sensors (Switzerland) |
| Volume | 17 |
| Issue number | 10 |
| DOIs | |
| State | Published - 12 Oct 2017 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2017 by the authors. Licensee MDPI, Basel, Switzerland.
Keywords
- Biosensor
- Reference electrode
- Self assembled monolayer
ASJC Scopus subject areas
- Analytical Chemistry
- Biochemistry
- Atomic and Molecular Physics, and Optics
- Instrumentation
- Electrical and Electronic Engineering