Abstract
High-voltage direct-current (HVDC) transmission systems are considered an outstanding solution due to high electrical losses emerging from long-distance transmission. However, HVDC transmission lines (TLs) are vulnerable to lightning strikes. In this work, the Yunnan-Guizhou 500 kV HVDC transmission system is used as a case study to evaluate the impact of lightning strikes on DC-TL overvoltages, as no research studies have been conducted to assess the lightning transient behavior of DC-TLs. A comprehensive investigation of the 500 kV DC-TL transient performance during lightning strikes is performed, taking into account different technical aspects that have not been studied in detail by previous researchers. Additionally, analysis of the back-flashover phenomenon has not been conducted well in previous work, and results on the effect of changing the lightning strike current peak and tower grounding resistance on shielding-failure flashover are quite limited. The distributed-parameter model is used to represent the DC-TL using the electromagnetic transients program (EMTP), considering real parameters of shielding wires and DC towers to study the lightning impact in the case of back-flashover and shielding-failure phenomena. Lightning strike is applied to the shielding wire, and the impact of increasing the peak value of lightning current is investigated on the back-flashover occurrence. Moreover, the influence of tower grounding resistance variation on the transient overvoltages across the tower body and back-flash-over phenomenon is evaluated. From the simulation results, increasing the lightning current peak and grounding resistance results in higher overvoltages across the tower body, which increases the probability of back-flashover. Additionally, the shielding failure of the TL is assumed, and the variation impact of the lightning current peak and grounding resistance on shielding-failure flashover is investigated. The results show that the impact of the lightning current peak has a more significant impact than the grounding resistance in the case of shielding-failure flashover.
| Original language | English |
|---|---|
| Article number | 1452 |
| Journal | Energies |
| Volume | 15 |
| Issue number | 4 |
| DOIs | |
| State | Published - 1 Feb 2022 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Back-flashover
- DC towers
- HVDC transmission
- Lightning overvolt-ages
- Lightning strikes
- Shielding failure
- Transient analysis
ASJC Scopus subject areas
- Renewable Energy, Sustainability and the Environment
- Fuel Technology
- Engineering (miscellaneous)
- Energy Engineering and Power Technology
- Energy (miscellaneous)
- Control and Optimization
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Evaluation of the Transient Overvoltages of HVDC Transmission Lines Caused by Lightning Strikes'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver