Abstract
An expression for the volumetric rate of entropy generation has been derived and displayed graphically to analyze the convection heat transfer for a fully established flow in a rectangular packed duct with L/H=16 and H/W=0.125. The top and bottom walls of the duct are heated by constant, asymmetric heat fluxes, while the other walls are insulated that is the L2 thermal boundary conditions. Entropy generation maps reveal the regions where excessive entropy generation occurs due to physical and geometric parameters for a specified task within the system.
| Original language | English |
|---|---|
| Pages (from-to) | 381-390 |
| Number of pages | 10 |
| Journal | International Communications in Heat and Mass Transfer |
| Volume | 24 |
| Issue number | 3 |
| DOIs | |
| State | Published - 1997 |
Bibliographical note
Funding Information:The authors wish to acknowledge King Fahd University of Petroleum & Minerals for funding the research project No. CHE/HEATFLUX/173 that resulted in generating this research. Nomenclature parameter given by equation (2), dimensionless specific heat at constant temperature, J kg "1 K -1
ASJC Scopus subject areas
- Atomic and Molecular Physics, and Optics
- General Chemical Engineering
- Condensed Matter Physics