Effect of high gamma dose on the PADC properties

  • F. Abu-Jarad*
  • , A. M. Hala
  • , M. Farhat
  • , M. Islam
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

The effect of the properties of PADC nuclear track detectors after exposure to high doses of gamma absorbed doses up to 5×105 Gray (50 Mrad) were studied. The gamma source was a 9.03 PBq (244 KCi), Co-60 source. Results indicate that each of the bulk etch rate (Vb), the tracks etch rate (Vt) and the sensitivity (V) of the detectors increases with the high gamma absorbed dose, but there is a drop in these parameters at the low gamma absorbed dose. Signs of surface roughness were observed by increasing the gamma absorbed doses and changes in color observed for doses larger than 2×105 Gray. The temperature of detectors during irradiation time reached 41°C. The fission fragment tracks (from Cf-252 source) disappeared quickly within the etching time (minutes) for total absorbed doses greater than 3×105 Gray due to their high bulk etch rate.

Original languageEnglish
Pages (from-to)111-114
Number of pages4
JournalRadiation Measurements
Volume28
Issue number1-6
DOIs
StatePublished - 1997

Keywords

  • Bulk etch rate and Track etch rate
  • High gamma absorbed doses
  • Sensitivity
  • Short etching time
  • Surface roughness

ASJC Scopus subject areas

  • Radiation
  • Instrumentation

Fingerprint

Dive into the research topics of 'Effect of high gamma dose on the PADC properties'. Together they form a unique fingerprint.