Skip to main navigation Skip to search Skip to main content

Design strategies of conventional and modified closed-air open-water humidification dehumidification systems

Research output: Contribution to journal › Article › peer-review

35 Scopus citations

Abstract

Humidification dehumidification (HDH) systems are robust and known to withstand a wide range of saline water without the need of complex maintenance. In this study, the closed-air open-water (CAOW) HDH arrangement is examined, which can easily be integrated with solar or other renewable resources. Also, this system is modified by incorporating heat recovery options for low performing units. The heat recovery process is executed through two approaches, (i) a mixing chamber and, (ii) by a heat exchanger. Thermal balancing through air extraction is evaluated for the basic as well as the modified cycles, particularly for high performing units. Zero, single and double extractions models are evaluated for the conventional CAOW water heated cycle. The performance of the systems is characterized into three operating regions (high, moderate and low) based on the effectiveness of the components. Based on the results of this evaluation, an operating scheme is then developed to decide where to use the conventional or the modified systems with or without extraction.

Original languageEnglish
Pages (from-to)114-127
Number of pages14
JournalDesalination
Volume435
DOIs
StatePublished - 1 Jun 2018

Bibliographical note

Publisher Copyright:
© 2017 Elsevier B.V.

Keywords

  • Desalination
  • Enthalpy pinch
  • Extraction
  • Heat recovery
  • Humidification-dehumidification

ASJC Scopus subject areas

  • General Chemistry
  • General Chemical Engineering
  • General Materials Science
  • Water Science and Technology
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Design strategies of conventional and modified closed-air open-water humidification dehumidification systems'. Together they form a unique fingerprint.

Cite this