Design, processing, and biocorrosion study of Ti–30Nb alloy with low elastic modulus for bioimplant applications

M. A. Hussein*, A. Madhan Kumar, M. A. Azeem, N. Ankah

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

This study aims to design and process Ti–30Nb at% alloy with improved biocorrosion protection and lower elastic modulus for use as a bioimplant material in orthopedic applications. The influence of sintering temperature on phases, microstructure, microhardness, and modulus of elasticity was investigated. The surface energy of the alloy was evaluated and the bio-corrosion study was carried out in a simulated body medium. According to the findings, Ti–30Nb alloy consisted primarily of β-Ti, with traces of α-Ti and α” phases. Increasing the sintering temperature enhanced the density and microhardness. The developed Ti–30Nb alloys have a modulus of (55–78.9) GPa, which is lower than that of commercial Ti6Al4V alloy and CP-Ti. The surface energy of the designed Ti–30Nb alloys was 18.5% more than that of the commercial Ti6Al4V alloy. The obtained in vitro corrosion results confirmed the beneficial impact of sintering temperatures on the enhancement of the corrosion protection of binary Ti–30Nb alloy.

Original languageEnglish
Article number128413
JournalMaterials Chemistry and Physics
Volume309
DOIs
StatePublished - 1 Nov 2023

Bibliographical note

Publisher Copyright:
© 2023 Elsevier B.V.

Keywords

  • Biomaterials
  • Corrosion
  • Microstructure
  • Powder metallurgy
  • Sintering
  • Titanium alloy

ASJC Scopus subject areas

  • General Materials Science
  • Condensed Matter Physics

Fingerprint

Dive into the research topics of 'Design, processing, and biocorrosion study of Ti–30Nb alloy with low elastic modulus for bioimplant applications'. Together they form a unique fingerprint.