Abstract
This paper proposes a new design of a dual-source multilevel inverter topology, comprising six switches, one diode, and three capacitors. With the mid-point available, it can be easily extended to a three-phase configuration. With sources configured as either symmetrical magnitude or asymmetrical magnitude, a sixlevel waveform can be generated. A total of three different mode of operation have been discussed for the proposed topology. Detailed simulation studies were implemented using PLECS to evaluate various operational scenarios. The proposed multilevel inverters exhibit lower total harmonic distortion (THD), improved efficiency, and a reduced number of components. The efficiency in all three modes of operation is more than 91 % up to the power level of 10 kW. The findings indicate that the suggested topology effectively facilitates the conversion of medium-voltage power in distributed energy systems.
| Original language | English |
|---|---|
| Journal | Proceedings of the International Middle East Power System Conference, MEPCON |
| Issue number | 2025 |
| DOIs | |
| State | Published - 2025 |
| Event | 26th International Middle East Power Systems Conference, MEPCON 2025 - Aswan, Egypt Duration: 20 Dec 2025 → 22 Dec 2025 |
Bibliographical note
Publisher Copyright:© 2025 IEEE.
Keywords
- Boost inverter
- SC-MLI
- boosting
- dual-source topology
- sixlevel
ASJC Scopus subject areas
- Safety, Risk, Reliability and Quality
- Energy Engineering and Power Technology
- Mechanical Engineering
- Control and Optimization
- Artificial Intelligence
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Design and Validation of Dual-Source Six-Switch Six-Level Multilevel Inverter Topology'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver