Skip to main navigation Skip to search Skip to main content

Design and performance evaluation of passive flow disruption techniques for Li-ion battery cooling

  • Shekh Abdullah*
  • , Yasser Rafat
  • , Nazrul Islam
  • , Yasser S. Alzahrani
  • , Faisal J. Alzahrani
  • , Mohd Nashrul Bin Mohd Zubir
  • , Alhussein M. Abdel-Hafeez
  • , Shafiqur Rehman
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

Abstract

Hybrid and electric vehicles are considered the future of the automotive industry. Lithium-ion (Li-ion) batteries are superior to conventional batteries due to their higher energy density, slower rate of self-discharge, and better stability. However, thermal management considerably affects the performance of Li-ion batteries, and if the produced heat is not distributed effectively, it may cause thermal runaway issues. Therefore, an effective thermal management system is required to maintain the battery module temperature within the recommended operating range. Air cooling remains an attractive thermal management strategy because of its simplicity, low cost, and ease of implementation; however, its thermal performance can be further improved through passive flow modification. This study offers a brief outline of many challenges inherent in thermal management. Air cooling is an effective thermal management strategy for maintaining the cell's temperature within an optimal functioning range under certain situations. In the present work, the effectiveness of an air-cooled Battery Thermal Management System (BTMS) was investigated by comparatively evaluating three passive flow disruption channels against a conventional straight channel. The User-Defined Function (UDF) was implemented the variable heat generation inside the prismatic cells. The numerical simulations were performed using the commercial code Fluent®. Three new cases were tested, and their performance was compared with the conventional channel. The efficacy of different augmented channel shapes was studied at two distinct Reynolds Numbers (Re) based on channel inlet length. The optimized channel shapes brought down the maximum temperature up to 3 °C throughout the length of the channel. Simulation results demonstrate that simple passive flow-disruption techniques provide incremental improvements in the thermal performance and temperature uniformity of conventional air-cooled lithium-ion battery modules while maintaining a simple channel configuration.

Original languageEnglish
JournalJournal of Engineering Research (Kuwait)
DOIs
StateAccepted/In press - 2026

Bibliographical note

Publisher Copyright:
© 2026 The Authors.

Keywords

  • Air Cooling
  • Battery Thermal Management System
  • Heat Generation
  • Li-ion battery
  • Transient
  • User-Defined Function

ASJC Scopus subject areas

  • General Engineering

Fingerprint

Dive into the research topics of 'Design and performance evaluation of passive flow disruption techniques for Li-ion battery cooling'. Together they form a unique fingerprint.

Cite this