Skip to main navigation Skip to search Skip to main content

Commercial polymeric fiber as sorbent for solid-phase microextraction combined with high-performance liquid chromatography for the determination of polycyclic aromatic hydrocarbons in water

Research output: Contribution to journal › Article › peer-review

52 Scopus citations

Abstract

A novel microextraction method making use of commercial polymer fiber as sorbent, coupled with high-performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons (PAHs) in water has been developed. In this technique, the extraction device was simply a length (8 cm) of a strand of commercial polymer fiber, Kevlar (each strand consisted of 1000 filaments, each of diameter ca. 9.23 μm), that was allowed to tumble freely in the aqueous sample solution during extraction. The extracted analytes were desorbed ultrasonically before the extract was injected into HPLC system for analysis. Extraction parameters such as extraction time, desorption time, type of desorption solvent and sample volume were optimized. Each fiber could be used for up to 50 extractions and the method showed good precision, reproducibility and linear response within a concentration range 0.05-5.00 μg L-1 with correlation coefficients of up to 0.9998. Limits of detection between 0.4 and 4.4 ng L-1 for seven PAHs could be achieved. The relative standard deviations (n = 3) of this technique were between 2.9% and 12.1%.

Original languageEnglish
Pages (from-to)7520-7526
Number of pages7
JournalJournal of Chromatography A
Volume1216
Issue number44
DOIs
StatePublished - 30 Oct 2009
Externally publishedYes

Bibliographical note

Funding Information:
The financial support from National University of Singapore is gratefully acknowledged. The authors would like to thank Professor Kiyokatsu Jinno (Toyohashi University of Technology, Japan) for providing the Kevlar fiber. The technical assistance of Madam Frances Lim is acknowledged.

Keywords

  • High-performance liquid chromatography
  • Polycyclic aromatic hydrocarbons
  • Polymeric fiber
  • Solid-phase microextraction
  • Water analysis

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Organic Chemistry

Fingerprint

Dive into the research topics of 'Commercial polymeric fiber as sorbent for solid-phase microextraction combined with high-performance liquid chromatography for the determination of polycyclic aromatic hydrocarbons in water'. Together they form a unique fingerprint.

Cite this