Skip to main navigation Skip to search Skip to main content

Coil embolization in 481 ruptured intracranial aneurysms: Angiographic and clinical results

  • Hasan Dinç*
  • , M. Halil Öztürk
  • , Ahmet Sari
  • , Ertuǧrul Çakir
  • , Gürkan Gazioǧlu
  • , Kayhan Kuzeyli
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

PURPOSE We aimed to report our 13-year experience with the embolization of ruptured cerebral aneurysms using detachable coils and postembolization angiographic and clinical results. MATERIALS AND METHODS Between June 1998 and September 2011, 481 patients with ruptured aneurysms were referred for endovascular treatment with detachable coils at our center. The technical feasibility, procedural complications, morbidity, mortality, and initial angiographic and clinical results were evaluated. RESULTS Endovascular treatment was successful in 95.6% of the patients. Postembolization angiography showed complete occlusion in 63.4%, a neck remnant in 30.8%, and incomplete occlusion in 5.8% of the aneurysms. A total of 331 patients were followed up. The overall angiographic results showed stable occlusion in 234 aneurysms (70.7%) and recurrence in 97 aneurysms (29.3%). During the follow-up period, stable angiographic occlusion was evident in 75% of the small, 61% of the large, and 38.5% of the giant aneurysms. Complications during the coiling procedure occurred in 75 procedures (15.6%). Ischemic complications were observed in 33 procedures (6.9%), and perforation of the aneurysm during the coiling occurred in 12 cases (2.5%). Five (41.7%) of 12 patients who had perforation during coiling died. The overall procedure-related morbidity and mortality were 5.6% and 2%, respectively. During the follow-up period, two patients (0.4%) had early rebleeding. None of the patients showed late rebleeding. In the follow-up, the retreatment rate was 12.6%. CONCLUSION Our data confirm the feasibility, safety, and efficacy of endovascular coil embolization in patients with ruptured cerebral aneurysms.

Original languageEnglish
Pages (from-to)165-172
Number of pages8
JournalDiagnostic and Interventional Radiology
Volume19
Issue number2
DOIs
StatePublished - 2013
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Coil embolization in 481 ruptured intracranial aneurysms: Angiographic and clinical results'. Together they form a unique fingerprint.

Cite this