Abstract

Central aortic blood pressure (CABP) is a very-well recognized source of information to asses the cardiovascular system conditions. However, the clinical measurement protocol of this pulse wave is very intrusive and burdensome as it requires expert staff and complicated invasive settings. On the other hand, the measurement of peripheral blood pressure is much more straightforward and easy-to-get non-invasively. Several mathematical tools have been employed in the past few decades to reconstruct CABP waveforms from distorted peripheral pressure signals. More specifically, the cross-relation approach together with the widely used least-squares method, are shown to be effective as a way to estimate CABP waves. In this paper, we propose an improved cross-relation method that leverages the values of the diastolic and systolic pressures as box constraints. In addition, a mean-matching criterion is introduced to relax the need for the input and output mean values to be strictly equal. Using the proposed method, the root mean squared error is reduced by approximately 20% while the computational complexity is not significantly increased.

Original languageEnglish
Title of host publication42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society
Subtitle of host publicationEnabling Innovative Technologies for Global Healthcare, EMBC 2020
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages2723-2727
Number of pages5
ISBN (Electronic)9781728119908
DOIs
StatePublished - Jul 2020
Externally publishedYes

Publication series

NameProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
Volume2020-July
ISSN (Print)1557-170X

Bibliographical note

Publisher Copyright:
© 2020 IEEE.

Keywords

  • Central aortic blood pressure
  • box constraints
  • eigenvalues
  • eigenvectors
  • multi-channel blind system identification
  • optimization
  • peripheral blood pressure

ASJC Scopus subject areas

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Fingerprint

Dive into the research topics of 'Blind Estimation of Central Blood Pressure Using Least-Squares with Mean Matching and Box Constraints'. Together they form a unique fingerprint.

Cite this