Abstract
We successfully reconstructed the horizontal and vertical beam emittances of a 160 keV low-intensity deuteron ion beam from the Energy Research Laboratory's low intensity duoplasmatron deuteron ion source. Reconstructions were made from horizontal and vertical beam width measurements. These measurements were done using only one quadrupole triplet and a beam profile monitor situated towards the end of the 45° beam line of the 350 kV ion accelerator. The deuteron beam emittances were ε{lunate}h = 67π mm-mrad and ε{lunate}v = 4π mm-mrad at 90% of the beam.
| Original language | English |
|---|---|
| Pages (from-to) | 383-389 |
| Number of pages | 7 |
| Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| Volume | 343 |
| Issue number | 2-3 |
| DOIs | |
| State | Published - 11 Apr 1994 |
Bibliographical note
Funding Information:This work is part of KFUPM/RI Energy Research Laboratory project supported by King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia .
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Instrumentation