Abstract

Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line. The overhead sections of mixed lines are exposed to lightning strikes. The lightning strikes can not only result in flashover of overhead line (OHL) insulators but can enter the cable and permanently damage its insulation if adequate insulation coordination measures are not taken. In this work, we have analyzed the factors that affect the level of overvoltage inside the cable by simulating a fast front model in PSCAD. It has been determined that surge arresters must be provided at cable terminals when the length of cable sections is less than 16 km to limit the core-ground overvoltage within the lightning impulse protective level (LIPL). The level of sheath-ground overvoltage is independent of the length of cable; however, it can be limited within LIPL by lowering the sheath grounding impedance to 1.2 W. Insulation coordination measures do not impact the likelihood of OHL insulators' flashover. The flashover performance of OHL can be improved by lowering the footing impedance of the second tower closest to the cable terminals, which is otherwise most likely to flashover.

Original languageEnglish
Article number4217
JournalEnergies
Volume12
Issue number21
DOIs
StatePublished - 5 Nov 2019
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2019 by the authors.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Cable overvoltage
  • DC transmission
  • Dielectric breakdown
  • Electromagnetic transient simulation
  • High voltage
  • Insulation coordination
  • Negative lightning strikes

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Fuel Technology
  • Energy Engineering and Power Technology
  • Energy (miscellaneous)
  • Control and Optimization
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Assessment of overvoltage and insulation coordination in Mixed HVDC transmission lines exposed to lightning strikes'. Together they form a unique fingerprint.

Cite this