Abstract
Retention angle measurements on 15 rectangular pin-fin tubes are made under static conditions (without condensation) using water, ethylene glycol and R-113. Condensate retention angles found to be considerably larger than the equivalent integral-fin tubes (i.e. with the same fin height, root diameter and longitudinal pin thickness and spacing) in a range of 5%-60%. An expression for condensate retention angle on pin-fin tubes was proposed and found to agree with the measured retention angles to within 15%.
| Original language | English |
|---|---|
| Pages (from-to) | 503-510 |
| Number of pages | 8 |
| Journal | Applied Thermal Engineering |
| Volume | 63 |
| Issue number | 2 |
| DOIs | |
| State | Published - 22 Feb 2014 |
| Externally published | Yes |
Keywords
- Condensate flooding
- Condensate retention
- Pin-fin tubes
- Retention angle
ASJC Scopus subject areas
- Energy Engineering and Power Technology
- Industrial and Manufacturing Engineering
Fingerprint
Dive into the research topics of 'An investigation of condensate retention on pin-fin tubes'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver