Abstract

This article proposes a plan to replace real-time power with constant power from the grid to reduce costs and reduce the impact of the micro-grid on the main grid at the same time. Most of the peak electricity consumption periods of universities or some enterprise institutions are during the daytime. If solar energy can be used reasonably at this time, it can provide a good guarantee of peak power. In this study, a grid-linked solar-plus-storage micro-grid was used to supply power to a university located in Okinawa, Japan. The non-dominated sorting genetic algorithm II (NSGA-II) was used to optimize the model size, and the loss of power supply probability (LPSP), life cycle cost (LCC), and waste of energy (WE) were taken as the optimization indicators. For this study, three scenarios were considered where the first scheme (Case 1) was a comparison scheme, which used a PV battery and real-time power from the infinity bus. Both the second and third cases used constant power. While Case 2 used constant power throughout the year, Case 3 used daily constant power. The optimal solutions for the power supply units were grouped into three cases where Case 1 was found to be the most expensive one. It was found that the costs of Cases 2 and 3 were 62.8% and 63.3% less than Case 1. As a result, the waste of energy was found to be more significant than Case 1: 70 times and 60 times, respectively. On the contrary, Case 1 had 15.2% and 16.7% less carbon emissions than Case 2 and Case 3, respectively. This article put forward the idea of constant power supply growth at the financial markets, which breaks the traditional way in which the power supply side follows the user’s consumption. While reducing costs, it reduces the impact on large-scale power grids and can also ensure the reliability of campus microgrids.

Original languageEnglish
Article number2853
JournalEnergies
Volume14
Issue number11
DOIs
StatePublished - 1 Jun 2021
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Keywords

  • Constant power supply
  • Microgrid
  • Multi-objective optimization
  • NSGA-II
  • Peak load shifting
  • Solar/battery/grid

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Building and Construction
  • Fuel Technology
  • Engineering (miscellaneous)
  • Energy Engineering and Power Technology
  • Energy (miscellaneous)
  • Control and Optimization
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'A comparative design of a campus microgrid considering a multi-scenario and multi-objective approach'. Together they form a unique fingerprint.

Cite this